Efectos de los cortocircuitos entre espiras de la máquina de inducción en la potencia instantánea

Fil: Yuchechen, Guillermo Daniel. Universidad Nacional de Misiones. Facultad de Ingeniería. Laboratorio de Investigación y Desarrollo en Energía Eléctrica; Argentina.

Bibliographic Details
Main Authors: Yuchechen, Guillermo Daniel, Mazzoletti, Manuel Armando, Bossio, Guillermo Rubén
Format: info:eu-repo/semantics/article
Language:Spanish
Published: IEEE Xplore 2018
Subjects:
Online Access:https://hdl.handle.net/20.500.12219/4163
id ir-20.500.12219-4163
record_format dspace
spelling ir-20.500.12219-41632024-05-27T00:30:58Z Efectos de los cortocircuitos entre espiras de la máquina de inducción en la potencia instantánea Yuchechen, Guillermo Daniel Mazzoletti, Manuel Armando Bossio, Guillermo Rubén Interturn short-circuit Induction machine Fault detection Instantaneous power Fil: Yuchechen, Guillermo Daniel. Universidad Nacional de Misiones. Facultad de Ingeniería. Laboratorio de Investigación y Desarrollo en Energía Eléctrica; Argentina. Fil: Mazzoletti, Manuel Armando. Universidad Nacional de Misiones. Facultad de Ingeniería. Laboratorio de Investigación y Desarrollo en Energía Eléctrica; Argentina. Fil: Bossio, Guillermo Rubén. Universidad Nacional de Río Cuarto. Facultad de Ingeniería. Grupo de Electrónica Aplicada; Argentina. En este trabajo se propone una metodología para detectar un cortocircuito entre espiras en los bobinados de estátor de la Máquina de Inducción (MI) trifásica utilizando la Teoría de Potencia instantánea. Para analizar los efectos de esta avería, se utiliza un modelo dinámico de la MI con falla que incluye un cortocircuito entre espiras en cualquiera de los bobinados de fase. A partir de las tensiones y las corrientes registradas a bornes de la máquina se usa la Teoría de la Potencia Instantánea con el fin de calcular la componente de corriente de potencia activa y reactiva en un marco de referencia α-β. Finalmente, se realiza la descomposición en redes de secuencia de las corrientes activa y reactiva para determinar los efectos de un cortocircuito entre espiras, particularmente, cuando la tensión de alimentación presenta el 5to armónico. Se presentan resultados de simulación con diferentes severidades de falla con tensiones de alimentación distorsionadas y, además, se analiza los efectos que producen los desequilibrios de tensión. In this paper, an interturn short-circuit fault detection strategy for Induction Machines (IM) by using the Instantaneous Power Theory is proposed. In order to analyze the effects of stator fault, a dynamic IM model including short-circuit fault in any of the phase-windings is used. Based on the voltajes and currents measured on the IM terminals IM, the Instantaneous Power Theory is used for calculate the active and reactive power current component in the α-β reference frame. Finally, the sequence decomposition of the active and reactive currents is performed to determine the effects of the stator fault, particularly when the power supply voltage is distorted with the 5th harmonic. Simulation results are presented with different fault severities for distorted power supply voltages and, in addition, the effects produced by the voltage imbalances are analyzed. 2018-12-17 info:eu-repo/semantics/article info:ar-repo/semantics/artículo info:eu-repo/semantics/publishedVersion https://hdl.handle.net/20.500.12219/4163 spa info:eu-repo/semantics/openAccess application/pdf application/pdf 872.9 KB IEEE Xplore
institution Universidad Nacional de Misiones
collection Repositorio RIDUNaM
language Spanish
topic Interturn short-circuit
Induction machine
Fault detection
Instantaneous power
spellingShingle Interturn short-circuit
Induction machine
Fault detection
Instantaneous power
Yuchechen, Guillermo Daniel
Mazzoletti, Manuel Armando
Bossio, Guillermo Rubén
Efectos de los cortocircuitos entre espiras de la máquina de inducción en la potencia instantánea
description Fil: Yuchechen, Guillermo Daniel. Universidad Nacional de Misiones. Facultad de Ingeniería. Laboratorio de Investigación y Desarrollo en Energía Eléctrica; Argentina.
format info:eu-repo/semantics/article
author Yuchechen, Guillermo Daniel
Mazzoletti, Manuel Armando
Bossio, Guillermo Rubén
author_facet Yuchechen, Guillermo Daniel
Mazzoletti, Manuel Armando
Bossio, Guillermo Rubén
author_sort Yuchechen, Guillermo Daniel
title Efectos de los cortocircuitos entre espiras de la máquina de inducción en la potencia instantánea
title_short Efectos de los cortocircuitos entre espiras de la máquina de inducción en la potencia instantánea
title_full Efectos de los cortocircuitos entre espiras de la máquina de inducción en la potencia instantánea
title_fullStr Efectos de los cortocircuitos entre espiras de la máquina de inducción en la potencia instantánea
title_full_unstemmed Efectos de los cortocircuitos entre espiras de la máquina de inducción en la potencia instantánea
title_sort efectos de los cortocircuitos entre espiras de la máquina de inducción en la potencia instantánea
publisher IEEE Xplore
publishDate 2018
url https://hdl.handle.net/20.500.12219/4163
work_keys_str_mv AT yuchechenguillermodaniel efectosdeloscortocircuitosentreespirasdelamaquinadeinduccionenlapotenciainstantanea
AT mazzolettimanuelarmando efectosdeloscortocircuitosentreespirasdelamaquinadeinduccionenlapotenciainstantanea
AT bossioguillermoruben efectosdeloscortocircuitosentreespirasdelamaquinadeinduccionenlapotenciainstantanea
_version_ 1800237293797113856